230 V Lighting Design Guide
22
Doc. 4859C | crestron.com
Module Installation
A licensed electrician, in accordance with all national and local codes, must mount the terminal blocks and modules
in a Crestron Automation Enclosure.
Terminal blocks are installed along the left side of single-wide enclosures and along the outside edges (left and
right sides) of double-wide enclosures. Modules are installed along the right side of single-wide enclosures and
side-by-side in the center of double-wide enclosures. When installing modules and terminal blocks in a
double-wide enclosure, invert units on the right side so that they can be properly wired. Refer to the illustrations
when considering the location of terminal blocks and modules within an enclosure.
CAUTION:
• This equipment is for indoor use only and needs to be air cooled. Mount in a well-ventilated area. The
ambient temperature must be 0° C to 40° C. The relative humidity must be 0% to 90% (non-condensing).
• Modules contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis–do not
touch PC board or components.
NOTES:
• Modules and terminal block must be installed into the lowest available spaces and continue toward the top
of the enclosure.
• Modules are installed after the enclosure has been completely wired.
Single Width Enclosure Mounting
Module and associated terminal blocks are installed in single width enclosure. The PAC2 processor occupies the
lowest module position.
PAC2 Processor in Single Width Enclosure Mount