Thermostats Crestron CHV-TSTAT and CHV-THSTAT
Sensor Setup Related Digital Joins (continued)
Signal Name Symbol I/O Definition
OMIT_LOC_HUM_F Advanced Output Asserted when Omitting built in hum sensor (THSTAT)
OMIT_R1_HUM_F Advanced Output Asserted when Omitting remote 1 humidity sensor
OMIT_R2_HUM_F Advanced Output Asserted when Omitting remote 2 humidity sensor
R1_H_OUTDOOR_F Advanced Output Asserted when remote 1 humidity sensor is outdoor
R2_H_OUTDOOR_F Advanced Output Asserted when remote 2 humidity sensor is outdoor
Problem Solving
Troubleshooting
The table below provides corrective action for possible trouble situations. If further
assistance is required, please contact a Crestron customer service representative.
CHV-TSTAT/CHV-THSTAT Troubleshooting
TROUBLE POSSIBLE
CAUSE(S)
CORRECTIVE ACTION
No power from
system
Check for +24V on pins 24(C)
and 24(R)
No display
Incorrect mounting to
backplate
Check thermostat mounting
No power to
thermostat
Check circuit breaker
Check 24V connection at
thermostat and at furnace/air
conditioner
Recheck wiring connections
Heating/Cooling
system not
operating*
Thermostat minimum
off times operating
both systems
Wait 5 minutes
Indicator displays
Heat On, but no
heat from register
Fan turns on when
furnace reaches
setpoint
Cannot change
temperature
setting
The upper or lower
temperature limits
were reached.
Wait five minutes, then recheck
registers.
Setpoint heat range is 38 – 90º F
(3-38º C).
Setpoint cool range is 59-100º F
(15 – 38º C)
Furnace cycles too
quickly
Anticipator setting
too low
Reprogram anticipator. Refer to
“Thermostat Setup” on page 14
High temperature
variance
Anticipator setting
too high
Reprogram anticipator. Refer to
“Thermostat Setup” on page 14
*H1, H2, C1, C2 may appear but the system will not activate until the 5 minute timer guards
have been satisfied.
32 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163