Crestron CHV-TSTAT and CHV-THSTAT Thermostats
SENSORS
Press the MODE button to access the SENSORS. Press VIEW to select each sensor
type. Press the Arrow keys (▲▼) to select the value of the parameter.
NOTE: The sensors are used for Temperature/Humidity Averaging. Choose USE to
include each sensor, or OMIT to exclude each sensor in the averaging equation.
Choose OMIT if the remote sensors are not installed.
NOTE: The thermostat will not leave the setup mode unless a valid sensor selection
is made.
MODE
VIEW
T
T
CRESTRON
SETUP: SENSORS
Sensor
Internal:
Remote 1:
Remote 2:
TEMP HUM
USE OMIT
USE OMIT
USE OMIT
Internal Sensor
Temperature/Humidity in CHV-THSTAT
Temperature only in CHV-TSTAT
Remote Sensors
CHV-RTS temperature only sensor
CHV-RTHS temperature/humidity sensor
Sensors may be indoor or outdoor.
Choose Use or Omit
Select Sensor Type
Temperature and/or Humidity
LOCAL MODE
Press the MODE button to access the LOCAL MODE SERVICE/TEST setup screen.
Press VIEW to select each parameter. Press the Arrow keys (▲▼) to select the value
of the parameter. This page bypasses all system delays and is used by the installer to
manually operate the HVAC system. Only one system can be run at a time.
NOTE: H1 – Single Stage Heating, H2 – Two stage Heating, C1 – Single Stage
Cooling, C2 – Two Stage Cooling.
MODE
VIEW
T
T
CRESTRON
SETUP: SERVICE/TEST
Heat Call:
Cool Call:
Aux Heat Call:
Humidifier Call:
Fan Run Call:
OFF
OFF
OFF
OFF
OFF
Heat Call
Choose Off, H1, or H2
Cool Call
Choose Off, C1 or C2
Fan Run Call (ON or OFF)
Aux Heat (ON or Off)
Only appears on heat pump systems
Humidifier Call (On or Off) CHV-THSTAT only
Press MODE button to return to the first screen. Simultaneously press and hold the
MODE and VIEW buttons to return to normal operation mode.
NOTE: Thermostat will not leave the setup mode until a valid sensor selection is
made.