Crestron 24 Volt DC Design Guide
10
Entire Building Designs
Crestron EMerge systems can be deployed across entire buildings without much extra
work, mostly due to the power and flexibility of infiNET EX.
• Up to 100 CLC-1DIMFLV2EX-24V devices can connect to a single control system
(MC3)
• Each CLC device acts as a wireless expander, effectively increasing range whenever
more infiNET EX devices are added to the wireless network
• The wireless indoor range is 100 feet from CLC device to CLC device
Optimizing Device Placement
• Each CLC-1DIMFLV2EX-24V is capable of controlling 1 or more fixtures. Since it
has 2 channels, it can control 2 lighting groups independently.
• You can connect as many fixtures to each channel that you would like, as long as
you do not exceed the maximum switch load rating of the CLC.
Crestron Model Load Rating (per channel)
CLC-1DIMFLV2EX-24V 2.5A @ 24VDC (60W)
65mA max current sink (0-10V output)