DCS 6000
User Manual
Danish Interpretation Systems DIS
Digital Conference System
CU 6005/6010/6011 Central Unit
Central Unit for series DCS 6000 Voting Units, Conference
Units, Interpreter Units, Ambient Noise Microphone, Channels
Selectors and Audio Output Units
Vista de página 0
1 2 3 4 5 6 ... 38 39

Resumo do Conteúdo

Página 1 - DCS 6000

DCS 6000 User Manual Danish Interpretation Systems DIS Digital Conference System CU 6005/6010/6011 Central Unit Central Unit for series

Página 2

Danish Interpretation Systems User Manual Manual 01 18 04438 10User Controls, indications & connectors Front plate layout The front plate layo

Página 3 - List of Contents

Danish Interpretation Systems User Manual Manual 01 18 04438 11  Buttons The buttons below and to the left of the display are used when stepp

Página 4

Danish Interpretation Systems User Manual Manual 01 18 04438 12Back Panel Layout Back Panel Connectors  Mains Power connector Connection for ma

Página 5 - Important

Danish Interpretation Systems User Manual Manual 01 18 04438 13 A selection is made in the Main menu by scrolling through the menu items with the

Página 6 - Warranty

Danish Interpretation Systems User Manual Manual 01 18 04438 14Delegate setup The “Delegate setup” menu comprises the following entries: • M

Página 7 - Features

Danish Interpretation Systems User Manual Manual 01 18 04438 15 More delegates will be put in the request queue when they press their

Página 8 - System components

Danish Interpretation Systems User Manual Manual 01 18 04438 16This setting is used to set the time from the delegate stops talking until the

Página 9 - Operating instructions

Danish Interpretation Systems User Manual Manual 01 18 04438 17 • Complete Lock With this setting an interpreter cannot switch on his microphone t

Página 10 - -Units info

Danish Interpretation Systems User Manual Manual 01 18 04438 18The Chain info menu displays information to the user about units connecte

Página 11 - Indications

Danish Interpretation Systems User Manual Manual 01 18 04438 19 The load is aborted with the Menu button and accepted with the Enter bu

Página 12 - Back Panel Connectors

Danish Interpretation Systems User Manual Copyright © 2007 DIS CU6005 6010 6011 REV V.DOC 16-07-2007 No part of this publication may be reprodu

Página 13 - Audio control

Danish Interpretation Systems User Manual Manual 01 18 04438 20The user returns to the main menu by pressing either the Menu button or the Enter b

Página 14 - Delegate setup

Danish Interpretation Systems User Manual Manual 01 18 04438 21 The LinelnLevel Adj has to be set as high as possible for maintaining the best S/

Página 15 - Manual 01 18 04438

Danish Interpretation Systems User Manual Manual 01 18 04438 22CU 6005 Central Unit General description The functionality of CU 6005 is basically

Página 16 - Interpretation setup

Danish Interpretation Systems User Manual Manual 01 18 04438 23 User Controls, indications & connectors Front plate layout Identical to the CU

Página 17 - Units info

Danish Interpretation Systems User Manual Manual 01 18 04438 24System Setup General guidelines Connect the CU 6005/6010/6011 to the various

Página 18 - Configuration

Danish Interpretation Systems User Manual Manual 01 18 04438 25 Maximum number of units to be connected The following table shows the maximum n

Página 19 - Firmware info menu

Danish Interpretation Systems User Manual Manual 01 18 04438 26Length of Feeding Cable, Type CAT5 AWG24 Length of Cable between each JB 6002,

Página 20 - Use with SW 6000

Danish Interpretation Systems User Manual Manual 01 18 04438 27 DC 6990P Conference Units – CU 6010/6011 The following table shows the maximum num

Página 21 - CU 6011 Central Unit

Danish Interpretation Systems User Manual Manual 01 18 04438 28MU 6040C/D and MU 6042D without connected loudspeaker – CU 6010/6011 This table

Página 22 - CU 6005 Central Unit

Danish Interpretation Systems User Manual Manual 01 18 04438 29 IS 6132P w/JB 6004 and LS 6032 – CU 6010/6011 Length of Feeding Cable, Type CAT5

Página 23 - Slot (extra)

Danish Interpretation Systems User Manual Copyright © 2007 DIS CU6005 6010 6011 REV V.DOC 16-07-2007 No part of this publication may be reprodu

Página 24 - System Setup

Danish Interpretation Systems User Manual Manual 01 18 04438 30Typical schematics The following schematics are showing various configurations: Sma

Página 25

Danish Interpretation Systems User Manual Manual 01 18 04438 31 Large size conference microphone system Microphone conference system with interpr

Página 26

Danish Interpretation Systems User Manual Manual 01 18 04438 32Microphone conference system with 3+1 ch. interpretation & IR, CU 6005 Microph

Página 27

Danish Interpretation Systems User Manual Manual 01 18 04438 33 Various configurations with RP 6004 Repeater and PS 6000 Power Supply

Página 28

Danish Interpretation Systems User Manual Manual 01 18 04438 34Small system with SW 6000 Conference Management Software

Página 29

Danish Interpretation Systems User Manual Manual 01 18 04438 35 Large system with SW 6000 Conference Management Software

Página 30 - Typical schematics

Danish Interpretation Systems User Manual Manual 01 18 04438 36Appendix Technical appendix Cabling CAT5 The DCS 6000 system uses CAT5, CAT5

Página 31

Danish Interpretation Systems User Manual Manual 01 18 04438 37 Important Please observe that either the RS232 Serial Connection or the RS42

Página 32

Danish Interpretation Systems User Manual Manual 01 18 04438 38Technical specifications Digital Section Sound quality ...24 bit audio @ 32

Página 33

Danish Interpretation Systems User Manual Manual 01 18 04438 39

Página 34

Danish Interpretation Systems User Manual Copyright © 2007 DIS CU6005 6010 6011 REV V.DOC 16-07-2007 No part of this publication may be reprodu

Página 35

Danish Interpretation Systems User Manual Manual 01 18 04438 5 Important Compliancy The equipment has been tested and found to comply with the lim

Página 36 - Appendix

Danish Interpretation Systems User Manual Manual 01 18 04438 6 To avoid moisture condensations do not install the unit where the temperature may r

Página 37 - Accessories (not supplied)

Danish Interpretation Systems User Manual Manual 01 18 04438 7 Description of the DCS 6000 system Features The DCS 6000 system has the follo

Página 38

Danish Interpretation Systems User Manual Manual 01 18 04438 8 System components The CU 6005/6010/6011 Central Unit supports all available units

Página 39

Danish Interpretation Systems User Manual Manual 01 18 04438 9 Operating instructions CU 6010 Central Unit General description The CU 6010 Central

Comentários a estes Manuais

Sem comentários