C2N-DB6/8/12 Keypad Troubleshooting
TROUBLE POSSIBLE
CORRECTIVE
The keypad does
not function.
The wrong power
supply is in use.
Use a Crestron power
supply.
receiving power, or
is receiving
insufficient power.
plugged into the NET
port is secure. Verify
that the power supply
is correct.
connection in the
network.
plugged into the NET
port is secure.
The keypad does
not function. All
feedback LEDs
are on low.
An improper Net ID
is used.
Verify that the
device’s Net ID
matches the Net ID in
the software program.
The keypad does
not function, or
does not function
as expected.
However, it
reports on
Cresnet at the
proper Net ID.
The unit is not
programmed
correctly.
Use SIMPL Debugger
to check the behavior
when buttons are
pressed. Revise and
reload the program as
needed to correct the
behavior.
mounted upside
down.
orientation.
(Continued on following page)