2-Series Integrated Wireless Control System Crestron MC2W
Ear Attachment for Rack Mounting (this image shows a 1RU device)
USE COVER SCREWS
4. Repeat procedure (steps 1 through 3) to attach the remaining ear to the
opposite side.
Bussing Strip Installation
The MC2W is supplied with a brass bussing strip to facilitate commoning (linking)
of multiple terminal block connections. The bussing strip is constructed with four
terminal block positions and may be trimmed to size for various applications or
different devices. One strip is supplied for the 8-position terminal block (four
relays).
1. To utilize the bussing strip, determine the number of relays to be
commoned for the equipment being installed. If less than four, the strip can
be trimmed to size with a pair of scissors or wire snips.
2. Loosen the terminal block screws and insert the first leg of the bussing strip
into the first common position of the terminal block. The strip engages the
other common positions automatically.
3. Remove approximately 1/8” of the jacket from the common wire and insert
the conductor into one of the terminal block common positions. Tighten the
terminal block screws to lock the wire and bussing strip into place. Insulate
the strip by folding a piece of ¾” wide vinyl electrical tape (such as Scotch
33+) over the spine and as much of the individual legs as possible. Excess
tape at each end of the strip should be pressed closed, then trimmed to
within approximately 1/16” of the end of the strip.
4. When wiring the remaining conductors, remove approximately 1/8” of the
jacket and insert the wires into the proper terminal block positions. To
prevent the possibility of electrical shorts, it is essential that these
conductors do not touch any uninsulated portion of the bussing strip.
5. Securing a tie wrap around the bussing strip is a useful way to provide
strain relief for the wires connected to the terminal block.
Stacking
Four “feet” are provided with the MC2W so that if the unit is not rack mounted, the
rubber feet can provide stability when the unit is placed on a flat surface or stacked.
These feet should be attached prior to the hookup procedure.
Hardware Hookup
Make the necessary connections as called out in the illustration on the following
page. Refer to “Network Wiring” on page 8 before attaching the 4-position terminal
block connector. Apply power after all connections have been made.
When making connections to the MC2W, consider the following:
• Use Crestron power supplies for Crestron equipment.
• The included cable cannot be extended.
10 • 2-Series Integrated Wireless Control System: MC2W Operations Guide – DOC. 6143A